Page view:
Nominal diameter
(mm)
Conductor tolerance
(mm)
DC meter resistance
(Ω/m,20℃)
Complete outer diameter(mm) Minimum breakdown voltage(V) Minimum elongation
(%)
Safety tension
(g)
Median Minimum value Maximum G1 G2 G3 G1 G2 G3
Minimum value Maximum Minimum value Maximum Minimum value Maximum
0.048  Conductor diameter is based on resistance 9.447  8.596  10.30  0.053  0.059  0.060  0.065  0.066  0.070  300 600 800 10 20.3
0.050  8.706  7.922  9.489  0.055  0.060  0.061  0.066  0.067  0.072  300 600 800 10 20.3
0.053  7.748  7.051  8.446  0.058  0.064  0.065  0.070  0.071  0.076  325 650 900 10 29
0.056  6.940  6.316  7.565  0.062  0.067  0.068  0.074  0.075  0.080  325 650 900 10 29
0.060  6.046  5.562  6.529  0.066  0.072  0.073  0.079  0.080  0.085  375 700 1000 12 29
0.063  5.484  5.045  5.922  0.069  0.076  0.077  0.083  0.084  0.089  375 700 1000 12 40.6
0.067  4.848  4.404  5.360  0.074  0.080  0.081  0.088  0.089  0.093  425 700 1100 13 40.6
0.070  4.442  4.050  4.890  0.077  0.083  0.084  0.090  0.091  0.096  425 700 1100 13 40.6
0.071  ± 0.003 4.318  3.941  4.748  0.078  0.084  0.085  0.091  0.092  0.097  425 700 1100 13 50
0.075  ± 0.003 3.869  3.547  4.235  0.082  0.089  0.090  0.095  0.096  0.102  425 850 1200 15 50
0.080  ± 0.003 3.401  3.133  3.703  0.087  0.094  0.095  0.101  0.102  0.108  425 850 1200 15 50
0.085  ± 0.003 3.012  2.787  3.265  0.093  0.100  0.101  0.107  0.108  0.114  500 900 1300 15 62.6
0.090  ± 0.003 2.687  2.495  2.900  0.098  0.105  0.106  0.113  0.114  0.120  500 900 1300 15 62.6
0.095  ± 0.003 2.412  2.247  2.594  0.103  0.111  0.112  0.119  0.120  0.126  500 950 1400 20 78
0.100  ± 0.003 2.176  2.034  2.333  0.108  0.117  0.118  0.125  0.126  0.132  950 1200 1400 20 78